[[Key Insights from 80 Essays]]
### Fundamentals & Market
- [[Next Generation Data Center]]
- [[Kinds of Data Centers]]
- [[Industries Benefiting from Data Center Set Ups]]
- [[Demand Drivers for Data Centers]]
- [[Data Center Opportunities]]
- [[India Data Center Revolution - A USD 600 Billion Opportunity]]
- [[The Unsustainable Data Center]]
### Reliability & Standards
- [[Data Centre Redundancy]]
- [[Data Center Tiers]]
- [[CE EU Standards]]
- [[ISO Standards Security x DC]]
- [[Site Set Up]]
- [[Site Acceptance Testing - SAT]]
- [[SAFE Modules]]
### Power Chain
- [[Power Infrastructure]]
- [[Single Line Diagram]]
- [[UPS Batteries]]
- [[Peak Power Output]]
- [[RMS]]
### Metrics & Measurement
- [[Data Centre Metrics]]
- [[Data Center Master Metrics]]
- [[Rack power Density]]
- [[Power Usage Effectiveness - PUE]]
- [[Thermal Design Power - TDP]]
- [[IT Load]]
- [[Power Consumption x Scalability]]
### Cooling Hierarchy
- [[Heat is the new constraint]]
- [[Cooling and Energy Efficiency Technologies]]
- [[Direct-to-Chip Cooling]]
- [[Immersion Cooling]]
- [[Two-Phase Cooling]]
- [[How AI Will Impact Energy Demand]]
- [[Data Centre Energy Demand]]
### Networking & Connectivity
- [[The Data Center is the Computer - How the Network Shapes Performance]]
- [[NVMe Fabric]]
- [[Active Optical Cable]]
- [[NIC - Network Interface Cards]]
### Compute Abstraction Stack
- [[VLSI]]
- [[Bare Metal]]
- [[VMs]]
- [[Docker Containers]]
- [[MIGs]]
- [[OpenCL]]
- [[Clustering]]
- [[Scheduling]]
### Multi-Tenancy & Utilisation
- [[multi-tenancy]]
- [[Instance]]
- [[Clusters vs Instances]]
- [[Racks]]
- [[10 MW DLC CW UPS T3]]
### The AI Stack
- [[The AI Stack - Building Blocks]]
- [[The AI Timeline - Navigating the Road Ahead]]
- [[Scaling Edge Physical AI - Bridging Cloud Intelligence with Real-World Systems]]
### Inference Architecture
- [[Inference]]
- [[AI Inference Infrastructure]]
- [[Nvidia-Groq - Inference Disaggregation Play]]
- [[Inference is Eating AI Compute]]
- [[Noisy Neighbour Problem]]
- [[Convenience-Control Tradeoff]]
### Modular DCs
- [[Modular Data Center Design Principles]]
- [[Elements of Modular DC Architecture]]
- [[Defining Modular DC Architecture]]
- [[Challenges in defining Modular DC Architecture]]
- [[Documenting Modular DC Architecture]]
---
### Directional Arrows of Progress
**Power Density per Rack**
`3-6 kW/rack → 20 kW/rack → 50 kW+ /rack`
Driven by GPU-dense AI workloads demanding more watts per square metre.
**Cooling Phase Shift**
`Air (CRAC/CRAH) → Rear-Door Heat Exchangers → Direct-to-Chip Liquid → Full Immersion → Two-Phase`
Each step handles roughly 3-5x more heat per rack unit than the last.
**Compute Disaggregation**
`Monolithic Server → Composable Infrastructure → Disaggregated Compute/Storage/Network`
Resources become independently scalable pools rather than fixed server bundles.
**Workload Slicing**
`Whole Server → VMs → Containers → MIGs (GPU Partitions)`
Granularity of allocation keeps shrinking, improving utilisation and multi-tenancy.
**Inference vs Training**
`Training-dominated capex → Inference-dominated opex`
As models mature, inference workloads overtake training in total compute demand.